Download Now
3PAR Multi-Path Device Specific Module Driver

3rd party Device Specific Modules (DSMs) will not claim Pure Storage FlashArray This includes EMC PowerPath, NetApp ONTAP DSM, HP 3PAR DSM or others. See the Installing Multipath-IO section for more details. To configure the installed multi-path device management software: General Data Protector and integration-specific limitations; Supported To prepare the Data Protector 3PAR StoreServ Storage integration for use with a Check that the P / 3PAR SMI-S Agent integration module is installed on. to configure the HPE 3PAR StoreServ Storage with Windows Server , Windows Server. , or Windows Connecting multiple paths for FC SAN boot. . referenced at the Storage Single Point of Connectivity Knowledge (SPOCK) website. . The script will modify only the devices whose Vendor String matches the.


3PAR MULTI-PATH DEVICE SPECIFIC MODULE DRIVER FOR WINDOWS 7

Type: Driver
Rating:
3.53
408 (3.53)
Downloads: 268
File Size: 28.6Mb
Supported systems: Windows 7/8/10, Windows XP 64-bit, Mac OS X 10.X
Price: Free* [*Free Registration Required]

Download Now
3PAR Multi-Path Device Specific Module Driver

Step 02 -- Configuring Multipath-IO for Windows Server 2008/2008R2

This document is divided into 3 sections. Refer to each section and follow the checklist given below and mark the task status as complete and NA if the recommendation is not applicable: GA or later ESX 6.

Upgrade will not proceed if any active to 3. As a best practice, HP recommends that the customer deploy configurations based on currently supported configuration. General understandings regarding Extended Support configuration sets: All discussion herein applies only to the components listed in this configuration set.

3PAR MULTI-PATH DEVICE SPECIFIC MODULE DRIVER FOR WINDOWS

As a best practice, HPE recommends that the customer deploy configurations based on currently supported configuration sets. Should a customer experience an issue with their configuration, HPE will expend Commercially Reasonable Efforts to determine root cause and provide a fix or workaround subject to the above limitations. Analysis of customer reported issues will include review of server, SAN, and storage array logs.

The only solution provided may be a workaround vs a product fix. The outcome of working an issue for an End-Of-Support-Life OS may be that the customer will be required to upgrade one or more components of their system i.

ESX 4. For each snapshot VV name specified, the command puts the snapshot in standby mode when updating the VV maps, and hosts may see disk resets while the VV is in standby mode.

3PAR Multipath Windows Userguide Command Line Interface (K views)

Normally, the VV will be in standby mode for a very short duration. Running concurrent updatevv sessions for VV sets or a list of VVs which have common VVs can have unpredictable results, including an unexpected node restart. Use updatevv only on one VV at a time for example, updatevv VV1. Failure to follow the below recommendations from Microsoft may lead to host losing access to storage.

3PAR array is not seen under DMP DSMs in Veritas Enterprise Administrator.

Read MS Article: The procedure for checking or changing load-balancing policy can be found at http: Furthermore, if only the boot disk is presented 3PAR Multi-Path Device Specific Module clustered disks are presentedthe system boots correctly. If one of the clustered disks is added, the passive node will hang during the reboot. Then when adding the clustered disks while the passive node is up and running, both Device Manager and Disk Manager hang during a re-scan.

The results to the active node are assumed to be the same if it is accessing a read-only copy of an RC group. This 3PAR Multi-Path Device Specific Module can occur in the following environment: These issues may be avoided or corrected by performing the following steps.

3PAR Multipath Windows Userguide

Perform the following on primary groups on both arrays: For the non-peer persistent group, the following policies need to be removed: The script sets the value to "0" essentially changing its policy to "online. HPE guideline is to mandatorily update to the latest Compatible version of Host Explorer before changing the host persona to This issue has not been observed when the Host Bus Adapters were connected to director class switches due to the much shorter timeframe associated with the HA Failover restart used by these switches compared to 3PAR Multi-Path Device Specific Module HAreboot restart used by the fixed port switches.

The path failure may not occur until the FOS upgrade or significantly later because the Name Server logout is prolonged. In cases where the path failure occurred sometime after the FOS upgrade, wherein no logical connection was made to the FOS upgrade, the trigger event may be any RSCN that occurs for any reason.

Step 02 -- Configuring Multipath-IO for Windows Server /R2/ - Pure1 Support Portal

Driver version 9. A resolution for systems containing the SNQ adapter will be made available in a future release.

Until this driver patch is available, the configuration using the 9. The workaround should be used until a driver is available.

  • 3 PAR Multipathing Best Practice with vSphere - VMarena
  • Step 02 -- Configuring Multipath-IO for Windows Server /R2 - Pure1 Support Portal
  • Step 02 -- Configuring Multipath-IO for Windows Server 2012/2012R2/2016
  • 23 for Microsoft Windows Users Guide for (IA64, x64, x86)

Pre-Upgrade recommendations: Hence, please plan to upgrade both the arrays within a minimal gap between the upgrades. Prior to the upgrade, it is recommended to failover to the other Cluster Node which will not be affected by the 3PAR Upgrade.

3PAR MULTI-PATH DEVICE SPECIFIC MODULE DRIVER FOR WINDOWS MAC

Post Upgrade Recommendations: Also the CLX Application must be upgraded to the supported version. Failing to do so, may cause an unexpected Cluster failover to be triggered causing Host outages. Failure to follow the below recommendations may lead to host losing access to storage.

Other Drivers